Final Report
Date: June 15, 1993
The University
of ARIZONA
Administration Office, 202 Building 90
Tucson, Arizona 85721
Telephone: (602) 621-235S
FAX: (602) 621-6366
To: David Webb - Doulton Water Filters
From:
Charles R. Sterling
Mike Yozwiak
Marilyn M. Marshall
Testing for Removal of Doulton Single Filter Housing with Ultracarb Candle for Removal of Cryptosporidium Oocysts.
Procedure:
The 8 1/2”
Ultracarb ceramic candle was inserted into the single filter unit housing
as instructed. The unit was then connected to a 5 gallon pressure vessel.
An initial pressure test was conducted by closing the terminal outlet,
filling tile pressure tank with 10 liters of dH2O and pressurizing the
system with 30 PSI of nitrogen gas. After checking for leaks, the 10 liters
were allowed to flow through the filter. After depressurizing the system,
the pressure vessel was filled with 10 liters of dH20 and seeded with
10(8) formalized oocysts (10(7)/L). The water was stirred to ensure a
homogenous distribution of oocysts. The system was again pressurized to
30 PSI and the water allowed to flow through the filter. Two liters were
allowed to pass through the filter. Liter #2 was saved for processing.
The outlet at the terminal end was shut off leaving the system under pressure.
After 16 hours, liters 3-5 were passed through the filter saving liter
#5 for processing. After leaving the system under pressure for 8 more
hours, liters 6-10 were passed through with liter #9 collected.
Each one liter sample was filtered through a lum pore size Nucleopore
polycarbonate membrane filter. The sample flask was washed with dH2O +
0.1% Tween 80 (washing solution) to remove any residual material. The
rinse was also filtered. Each filter was carefully removed and placed
in a 50 ml conical tube (tube A). The filter was washed and vortexed 3
times. After each wash the contents were placed into another 50 ml conical
tube (tube B). The volume in tube B (45-50 ml) was concentrated by centrifugation
(3000 rpm in a Sorvall T-6000B centrifuge for 10 minutes). The liquid
portion was aspirated down to 1 ml, then mixed to resuspend the pellet.
This pellet is a 1:1000 consentration of the original liter and represents
a theoretical oocyst count (assuming no oocysts were trapped by the filter)
of 10(10) oocysts/ml. Samples of the suspension were then placed in a
hemacytometer and counts were made in triplicate at 400X mag. giving a
particle concentration in oocysts per ml. This figure was then multiplied
by the final volume of the suspension to give the total number of oocysts
recovered. This number was divided by the seeded concentration value times
100 to calculate the percentage or oocyst removal.
Tap water
NTU = 0.2
pH = 7.8
TDS = 630mg/L
T0C = 3.4mg/L
Table 1: | Removal or Cryptosporidium oocysts | |
Sample | #
Oocysts Recovered |
Percentage Removal |
1) Liter #2 | none | 100% |
2) Liter #5 | none | 100% |
3) Liter #9 | none | 100% |
No oocysts
were found in any of the samples tested (100% removal). This represents
a greater than 6 log reduction of oocysts.
Liter #2 did contained a fairly large amount of black and white particulate
matter, enough to produce a solid black pellet (pellet mass was approximately
5mm x l.5mm) when the liter was concentrated. The amount or particulate
matter decreased only slightly in liter #5 and was a little less evident
in liter #9.
Discussion:
This filter
unit performed very well and far exceeded the EPA recommended
3 log reduction (99.9% removal) or parasitic cysts.
The black and white particulate matter round in each sample was carbon
and ceramic which had been washed from the filter. This occurred even
after the candle had been flushed with 10 liters of water prior to the
start or the testing phase. It would be recommended therefore that more
water flushing (more than 19 liters) be done on new units to remove this
loose particulate matter prior to use. There were no detectible external
leaks.