Pesticides and Herbicides

Procedures - Mains tap water was passed through the filter at 1 litre per minute. Using a dosing pump, solutions of the organic compounds in methanol were bled into the tap water flow above the filter. The input concentration in the effluent measured after filtering on samples taken after 10, 500, 1000, 2000 and 5000 litres.

Analysis - (organochlorine pesticides) The samples were extracted with pentane and extracts dried and concentrated using a Kuderna-Danish evaporator. Analysis was by EC-GC using a 25M WCOT column coated with OV1. The peaks were compared to those of standards passed through the same procedure. (Triazines) The samples were made alkaline with ammonia and the extracted with dichloromethane. The extracts were dried and concentrated and examined by gas chromatography using a polar capillary column (PEG 20M) and a nitrogen-selective detector. The peaks obtained were compared with those of standards treated in the same manner.

Results

Compounds
Input conc.
ug/L
Conc. after passing
stated litres
% reduction at
stated litres
x
x
10 500 1000 2000 5000 2000 5000
Lindane
10
<0.1 <0.1 <0.1 0.5 0.3 95 98
Heptachlor
10
<0.1 <0.1 <0.1 <0.1 0.3 >99 >97
Dieldrin
10
<0.1 <0.1 <0.1 <0.1 0.1 >99 99
pp'DDT
10
<0.1 <0.1 <0.1 <0.1 <0.2 >99 98
PCB (aroclor 1260)
10
<0.2 <0.2 <0.2 <0.2 <0.2 >98 >98
Atrazine
10
<0.1 <0.1 <0.1 <0.1 <0.1 >99 >99
Simzine
10
<0.1 <0.1 <0.1 <0.1 <0.1 >99 >99

The Doulton U5 (Supercarb) filter candle gives excellent performance in removing this group of pesticides and herbicides. More than 95% of the added pesticides and herbicides are removed after 2000 and 5000 litres has passed through the filter candle.

Signed

David Meek for SAC Scientific
15.7.1987