TECHNICAL DATA

 

Displacement

 

     50 Hz operation

3.4 ft3 min-1 (5.8 m3h-1)

     60 Hz operation

4.1 ft3 min-1 (7.0 m3h-1)

 

Speed (Pneurop 6602)

 

     50 Hz operation

3.0 ft3 min-1 (5.1 m3h-1)

     60 Hz operation

3.6 ft3 min-1 (6.2 m3h-1)

 

Ultimate vacuum (total pressure)

Gas ballast

High vacuum mode

High throughput mode

Closed

1.5 x 10-3 torr

2.3 x 10-2 torr

 

2 x 10-3 mbar

3 x 10-2 mbar

Low flow, I

2.3 x 10-2 torr

6 x 10-2 mbar

 

3 x 10-2 torr

6 x 10-2 mbar

High flow, II

 

9.1 x 10-2 torr

 

 

1 x 10-1 mbar

 

Inlet connection

NW25

 

Outlet connection

NW25

 

Maximum allowed outlet pressure

14 psig (1 bar gauge)

 

Maximum allowed inlet and gas ballast pressure

7 psig (0.5bar gauge)

 

 

Maximum water vapor inlet pressure

38 torr (50 mbar)

 

Maximum water vapor pumping rate

 

     Gas ballast low flow

60 gh-1

 

     Gas ballast high flow

220 gh-1

 

Motor power

 

     50Hz

250 W

     60Hz

300 W

 

Electrical supply

 

1-phase

110-120 V or 220-240V,

 

50 or 60 Hz

3-phase

200-230 V or 380-460V,

 

50 or 60 Hz

 

Operating temperature range

12 - 40 oC

 

Weight, without Oil

43 lbs (21.5 kg)

 

Noise

48 dB(A)

 

Oil capacity

 

     Maximum

0.71

     Minimum

0.421

 

Recommended oil (supplied)

Ultragrade 19